Receiver FSE 736 radiobus®
Max. number of control commands |
36 digital or 10 analog (max. number of additional digital commands depending on configuration) |
Unique system addresses |
Over 1 000 000 combinations |
Supply voltage (see type plate) |
42 – 115 V AC 100 – 240 V AC |
Power consumption |
Max. 38 W |
Inputs |
Analog / digital: depending on equipment with input modules |
Outputs |
- |
Interfaces |
CANopen, Profibus-DP, RS485, RS232, DeviceNet, SAE J1939, Profinet, IQAN Cable option |
E-STOP resp. Si1, Si2 control unit |
1 x E-STOP output, 2 relays 4 A |
Safety function |
E-STOP: Performance Level d, category 3 according to EN ISO 13849-1:2008 |
Frequency ranges |
405 – 475 MHz1, 865 – 870 MHz, 902 – 928 MHz, 1210 – 1258 MHz1 2,4 GHz: 2402 – 2480 MHz |
Channel spacing |
12.5 / 20 / 25 / 50 / 250 kHz 2,4 GHz: 1 MHz |
Connection |
Harting Han 32 or Han 50 Option: cable glands (metric M20/32) |
Antenna |
External, FL 30 or FL 70 Option: car antenna with 5 m cable and BNC connector |
Operating temperature range |
-20 °C … +60 °C |
Housing material |
Aluminum |
Dimensions |
270 x 160 x 115 mm (10.6 x 6.3 x 4.5 inches) |
Weight |
Max. 3.5 kg (7.7 lbs.) |
Protection class |
IP 65 |
Certificate No. |
IBExU11ATEXB007 X |
Marking |
II 3G Ex nA nC IIC T4 X Gc II 3D Ex t IIIC T 80 °C Dc |